Field Repairs & Alterations

Question: 

I have mono trusses on either side of a firewall. I have the fire rating/wall material between them. Can I place a ridge vent above these two? Or should I use vents? How do I calculate the appropriate vent sizes and styles?

Question: 

We are planning to add 1/2 in. cement board and 3/8 in. quarry tile to a kitchen floor. We need to know if the floor trusses will handle the additional weight. The floor trusses are 19.2 in. O.C. and the loading numbers are 40-10-0-5. What do these numbers mean?

Question: 

Occasionally we deal with truss failures due to impact and or crushing forces such as trees falling onto roof structures. At what point can the truss no longer be repaired? Also, what should an adjuster look for when determining repair-ability? Or should a storm adjuster basically punt and call a consultant for every truss failure?

Question: 

I am a professional engineer looking for information concerning the failure of metal plate connected wood trusses and methods of repair. I am looking for this information with regard to developing recommendations for the repair of truss systems in the floor structures of two-story multi-family dwellings. I see frequent failure of truss systems of this type in both in bending and due to catastrophic failure at the gussets.

Question: 

Can I put a wood deck (1/2 in. plywood) on top of the bottom chord of a 26 foot span truss 24 inches on center?

Question: 

Our home caught fire last month and burned partly through a tongue and groove ceiling to the trusses. Some are charred. Our contractor did a moisture meter test. An engineer for the insurance company said the trusses were only smoke damaged & the moisture meter test is invalid (it can be set to read anything). I found one article on charred trusses, but it’s pretty vague. We do not feel safe with the insurance engineer’s assessment because some of the trusses are obviously charred. We hired an engineer who agreed with us.

Question: 

I am a structural engineer designing pool cage structures that are typically attached to the house at the fascia board. Sometimes, the structure is attached where trusses are behind the fascia board and other times there is a framed gable end overhang. Do you know of any information concerning this additional load on the trusses or overhang under design wind loads? Is there a limiting distance on the amount of overhang? I know trusses are designed for certain uplift and the pool cage will add to this uplift at design load, but what about the gable end overhangs?

Question: 

How often are trusses repaired?

Question: 

As a home inspector, I have recently inspected an existing home with an attic truss system installed. Several of the truss web members have been cut away to allow access to an attic-mounted heating system. Can you recommend repairs to a truss with cut web members?

Question: 

How do trussed roofs perform in long-term service? Are there any reports of rusting in the nail plates, rot/insect attack, do-it-yourself modifications, or condensation and ventilation problems in the attic?