Fire Resistance

This research report evaluates the use of L-shaped partition intersections as an equivalent alternative to the Ushaped intersections typically shown in fire-resistive assembly evaluation reports.

Getting information up front on sprinkler systems can ease the design process.

Remember: when you calculate the fire resistance of component assemblies, you have options!
 

Since FRTW studs are allowed in wall assemblies that are otherwise defined as non-combustible, building and truss designers often confront the question does a joint between the wall and the roof or floor assembly mean that those elements of the building also require noncombustible material, like FRTW? To answer this, we need to study the IBC

This presentation seeks to explain how to correctly apply live loads to the bottom chord of trusses for uninhabitable attics in accordance with IRC Table R301.5 and IBC Table 1607.1 and ASCE 7-10 Table 4-1.

This report focuses on building code requirements for using fire retardant treated wood (FRTW) in floor/ceiling and roof/ceiling assemblies in Type III building construction. 

This research report will focus on manufacturer or trade association deflection requirements for a number of floor topping/covering related products where deflection requirements may impact serviceability.

This presentation provides an overview of fire-rated assemblies that include wood trusses. Topics covered include assembly testing, Harmathy’s rules, and an examination of fire performance in the field. 

Question: 

A question has come up concerning sloped roof trusses and fire assembly ratings. Some are reluctant to rely on test results from flat (parallel chord) trusses applied to sloped roof trusses. Do you have any information regarding the suitability of the fire rated ceiling assemblies for sloped roof trusses? Does the “minimum depth” requirement of the parallel chord assembly apply to the minimum depth of a sloped roof truss (i.e., heel height?)

Question: 

Our home caught fire last month and burned partly through a tongue and groove ceiling to the trusses. Some are charred. Our contractor did a moisture meter test. An engineer for the insurance company said the trusses were only smoke damaged & the moisture meter test is invalid (it can be set to read anything). I found one article on charred trusses, but it’s pretty vague. We do not feel safe with the insurance engineer’s assessment because some of the trusses are obviously charred. We hired an engineer who agreed with us.