Question: 

What are the health hazards of black fungus on Douglas-Fir lumber?

Question: 

I was working on a job that had trusses that span more than 78 ft. with a 9/12 pitch. We had the #5 truss being installed when the #4 truss gave way. The trusses that were being installed are a two part system. The bottom set is what you would call hip trusses. The trusses contained 2x6 bottom chords, 2x8 top chords and rafters, and 2x4 webs. The roof sheathing was to be 3/4 in. plywood, 15 lb. felt paper and roof shingles. The ceiling was to be 5/8 in. drywall. The #4 truss sheared about 1 in. off the wall.

Question: 

I am looking for some information regarding black surface mold on lumber. Does it alter the integrity of the lumber stress values? I have a client who wants to use “all dry” lumber for his construction but I do not know if this is really necessary.

Question: 

I need to obtain some information on fire-retardant-treated roof trusses.

Question: 

Our home caught fire last month and burned partly through a tongue and groove ceiling to the trusses. Some are charred. Our contractor did a moisture meter test. An engineer for the insurance company said the trusses were only smoke damaged & the moisture meter test is invalid (it can be set to read anything). I found one article on charred trusses, but it’s pretty vague. We do not feel safe with the insurance engineer’s assessment because some of the trusses are obviously charred. We hired an engineer who agreed with us.

Question: 

If the truss design drawing specifies using 2x4 1650F SPF, can 2x4 No. 2 southern pine be used instead? What are some things that need to be checked?

Question: 

I am thinking of using wood trusses for the roofing/ceiling structural systems on some houses I shall build. I remember, though, an engineer/volunteer fireman commenting back in 1989 that the connector plates are prone to expand and pop off, early on in a fire, causing catastrophic structural failure. Was this the case, and if so, has this problem been corrected?

Question: 

What does KD-HT mean?

Question: 

We have been using Turb-O-Webs for about four months. We are very happy with their performance, although there have been a few ripples along the way. The main thing that concerns me at present is the need for performance documentation and testing data. Do you have anything that will help, or know of people or organizations that could offer assistance?

Question: 

In a small scale multi-family residential project, I'd like to use a wood truss floor-ceiling assembly to achieve a one hour separation between units. I'd like to directly attach the drywall to the underside of the trusses & use the truss space for ducts & lighting (the floor above will be lightweight concrete on plywood sub-floor). UL assemblies do not seem to address the duct/light penetrations in such an assembly. Can I achieve a one-hour rating in such an assembly and how are penetrations addressed? Can the ducts in the truss space serve both units above and below?