Performance

Question: 

I have a four-year-old house with glued open-web trusses. Both the truss manufacturer and the builder have admitted to me that the trusses were installed wrong. I have a problem with the suggested repair. I have hired a structural engineer and he suggested installing a 2x10 between each truss and removing the old truss. This would have to take place on both the first and second floors because all the trusses were installed wrong. The manufacturers want to install six strongbacks on each floor, hoping this will tighten them up.

Question: 

I am looking for a 1-hour roof/ceiling assembly for wood truss construction. I would like to apply the drywall directly to the bottom of the truss and also have insulation for sound control. Is this possible without using channels and what UL number would I use?

Question: 

I am investigating a roof failure in a 22-year-old structure. The connector plates have peeled open like a banana skin in several instances. The teeth do not appear sheared or torn at the wood surface. However, the plates will be in firm to one member and separated in the other (a gap of about 1/32 in.). Although there are large deformations, the roof is still standing. There was a heavy snow before the problem became apparent. Do you have any insights?

Question: 

I have built a 30 ft. x 40 ft. pole barn with nine 30 ft. 2x4 7/12 pitch trusses that are 5 ft. O.C. I am planning to finish out the interior and will attach 7/16 x 4 x 8 OSB sheets to the trusses for my ceiling. Along with this, I will have to add several 2x4 nailers across the 30 ft. span between the trusses to attach the sheeting to. My question is: will these trusses have any problem supporting this ceiling? I am not planning on anything being placed in the section above the ceiling and there will be no walls or supports erected between the ceiling and the floor.

Question: 

Does SBCA have any guidelines regarding the size of a room in an attic truss? I have used a formula, length of room in inches divided by the depth of the bottom chord equaling less than 22. I was curious if any extensive studies or published articles giving more exact guidelines are available.

Question: 

How much OSB can be stacked on a floor deck without damaging the trusses?

Question: 

We are having a house built and on a recent visit we brought along a friend who builds houses for a living. He noticed that the trusses were wet and a bit moldy. The wood seemed warped, brown, and had white splotches on it. We are worried that it would later make the roof uneven. How could we tell how long the trusses have been exposed to the elements? What options do we have from here? Do we request new trusses, or can these be repaired?

Question: 

We have designed a custom home that needs a good solid floor, with low vibration perceptibility. The system we have specified consists of 2 in. of gypcrete over 1 and 1/8 in. thick plywood or OSB. The floor trusses are 20 in. deep at 16 in. O.C., spanning 31 ft. 6 in. The preliminary truss design shows a double top and bottom chord with a total load deflection of 1.30 in. (l/290) and a live load deflection of 0.65 in. (l/581). The basement ceiling will be 1/2 in. gypboard nailed to the bottom of the trusses.

Question: 

The truss industry maintains that the design of truss roof and floor system permanent bracing is the responsibility of the building designer. System permanent bracing covers the entire structure and all bracing element interactions.

Question: 

We have a local builder wishing to use floor trusses with a 2-hour assembly. I have shown him the 2-hour design on pages 17-27 of the second edition of SBCA’s Metal Plate Connected Wood Truss Handbook. Is this assembly UL approved? If so, what is the design number?