Question: 

Is finger-jointed material allowed in the manufacturing of trusses?

Question: 

How high would a truss have to be to span 33 feet 9 inches?

Question: 

Does the NFPA sprinkler standard address sprinkler loading? If so, how and where do I buy it? What other information do you have on sprinkler loading? How do other truss companies price jobs for sprinkler loading the plans do not include a sprinkler layout or even say what size/type of sprinkler system will be used?

Question: 

I would like to know if there is an age restriction on wood trusses. How long after production are they safe to use? The trusses in question are at least three to four months old. Are they still safe to use? They have not been covered the entire time and are showing signs of age.

Question: 

IBC 2012/2015 2303.4.6 and IBC 2012/2015 2303.4.7 state: 
2303.4.6 TPI 1 specifications. In addition to Sections 2303.4.1 through 2303.4.5, the design, manufacture and quality assurance of metal-plate-connected wood trusses shall be in accordance with TPI 1. Job-site inspections shall be in compliance with Section 110.4, as applicable.

Question: 

Can I put a wood deck (1/2 in. plywood) on top of the bottom chord of a 26 foot span truss 24 inches on center?

Question: 

Is it possible to retrofit a standard rafter/joist style roof to a scissors truss configuration without replacing the existing construction?

Question: 

If trusses blew down from insufficient temporary bracing and the contractor put them back up without the knowledge of the truss manufacturer and gave the truss manufacturer a letter stating that the trusses were okay, is that sufficient? Do you know of any truss manufacturer who would accept this?

Question: 

What are the requirements for installing “valley set” overlay roof trusses? I am interested in nailing and support conditions. Some engineers ask for the bottom chord of the valley truss to be ripped to match the roof pitch of the underlying trusses. Is this necessary?

Question: 

We would like to know if there is a problem with using wood floor trusses with masonry bearing walls without a ledger. Our local supplier has told me that encasing the wood truss in the masonry wall could be detrimental to the truss due to moisture. What, if any, suggestions do you have for this condition? If a bottom chord bearing is used, do the trusses need fire cuts? The two-story building contains masonry bearing walls with wood trusses on the second floor and wood trusses at the roof.