Business Logistics

Question: 

Is the truss designer or the building designer responsible for calculating snow drift loads on a roof system?

Question: 

What does “P.E.” stand for in building construction?

Question: 

My framers are always complaining that the “trusses are bad.” I am looking for tolerance information that not only addresses the allowable variance in length and height, but also allowable variation in the top chord with regard to straightness (i.e. how straight should a pull string line from the top and bottom of top chord be?). Also, if trusses are set on a perfectly level wall, what variation is allowed from truss to truss (i.e. if I put a 10 ft. straight edge perpendicular to the trusses, how much can they vary in height, not just at peak or bottom but all along the top chord)?

Question: 

How much weight can a wood truss hold, when it’s made with 2x4 material and spans 36 ft. with a 4/12 pitch. I would like to hang things from the ceiling and am wondering if it is safe. I live in an area where there are heavy snowstorms. Also, how much exposure to the weather can a truss handle before there is a problem?

Question: 

What is the industry standard for ordering residential roof truss systems: Should the general contractor/builder field measure before ordering trusses or should he rely on the blueprint? Who is responsible for their accuracy – the plan service, the truss manufacturer, the builder/general contractor or the framing contractor?

Question: 

I'm trying to find out who the truss manufacturer was that built the trusses in my home. I was told that there is usually a stamp on the side of the bottom chord. All I found was “2400F 2.0E.” What am I looking for? The other chords only have material stamps. Can you tell me what kind of information I should be looking for to find out who the manufacturer was?

Question: 

What is the recommended way to frame gable end overhangs?

Question: 

Do you have information on purlin grades and species to meet 50 psf top chord live load using 2x4s on edge 24 in. O.C. over trusses at 6 ft. O.C.?

Question: 

A condominium project I am involved with is experiencing a sound transfer problem through the floor/ceiling assembly between the first and second floor. You can hear every footstep, from an adult to a child. The floor assembly consists of a carpet and pad, 3/4 in. OSB sub-flooring, 15 in. deep wood trusses at 16 in. on center, 9 in. fiberglass batt insulation and a 5/8 in. gypsum board ceiling. The trusses span 20 ft. with air/heat ducts between the trusses. Will an additional layer of 5/8 in. gypsum board attached to 7/8 in.

Question: 

We have been specifying laminated veneer lumber (LVL) beams for some time now. The plans usually state, “Beam to be engineered and supplied by truss manufacturer.” What kind of liability issues do I need to watch out for?