Business Logistics

Question: 

Are there any typical wood truss span tables for roofs and floors available? Standard framing details for use in preliminary design?

Question: 

I am planning a 36 ft. x 60 ft. clear-span horse barn with posts set 12 ft. O.C. If I use 2x6 verses 2x4 wood trusses what would the proper spacing be? The roofing is 29 ga. K-panels metal with insulation, and winter snowfall is minimal in our area.

Question: 

Is it possible to retrofit a standard rafter/joist style roof to a scissors truss configuration without replacing the existing construction?

Question: 

I stamp the bottom chord of my trusses with my company name and the name of my third-party inspector. Recently, my local building inspector requested another stamp with the on-center spacing, the total design load and the load duration factor. I have never heard of this before and I was wondering if you had any further information on this requirement.

Question: 

Our home caught fire last month and burned partly through a tongue and groove ceiling to the trusses. Some are charred. Our contractor did a moisture meter test. An engineer for the insurance company said the trusses were only smoke damaged & the moisture meter test is invalid (it can be set to read anything). I found one article on charred trusses, but it’s pretty vague. We do not feel safe with the insurance engineer’s assessment because some of the trusses are obviously charred. We hired an engineer who agreed with us.

Question: 

In our one-year-old home, as you approach the hallway, the floor slopes downward. Our home inspector said that this was most likely due to the fact that the walls were resting on the floor as opposed to being load-bearing walls. What has been your experience with sloping floors in a new home? The floors are very flat elsewhere until the walls start. Do you think this sloping could turn into a structural problem eventually?

Question: 

We have designed a custom home that needs a good solid floor, with low vibration perceptibility. The system we have specified consists of 2 in. of gypcrete over 1 and 1/8 in. thick plywood or OSB. The floor trusses are 20 in. deep at 16 in. O.C., spanning 31 ft. 6 in. The preliminary truss design shows a double top and bottom chord with a total load deflection of 1.30 in. (l/290) and a live load deflection of 0.65 in. (l/581). The basement ceiling will be 1/2 in. gypboard nailed to the bottom of the trusses.

Question: 

I own and live in the middle unit of a one-story tri-plex that has a truss-framed roof. The interior has high ceilings that would potentially allow the addition of a second floor room. I am contemplating adding a shed dormer to create a second story bedroom. Do you have any suggestions as to how a shed dormer could be added? I am familiar with how to frame up a shed dormer if the original framing were rafters and a ridge board, but the truss construction has thrown me for a loop.

Question: 

The lumber used in most metal plate connected wood trusses is either visually- or mechanically-graded solid sawn dimensional lumber. However, the Truss Plate Institute's ANSI/TPI 1 allows the use of structural composite lumber (SCL) products such as laminated veneer lumber (LVL), laminated strand lumber (LSL) and parallel strand lumber (PSL). These engineered wood products can conceivably compete with sawn lumber and complement it in truss designs.

Question: 

If trusses blew down from insufficient temporary bracing and the contractor put them back up without the knowledge of the truss manufacturer and gave the truss manufacturer a letter stating that the trusses were okay, is that sufficient? Do you know of any truss manufacturer who would accept this?