Business Logistics

Question: 

What is the industry standard for ordering residential roof truss systems: Should the general contractor/builder field measure before ordering trusses or should he rely on the blueprint? Who is responsible for their accuracy – the plan service, the truss manufacturer, the builder/general contractor or the framing contractor?

Question: 

I'm trying to find out who the truss manufacturer was that built the trusses in my home. I was told that there is usually a stamp on the side of the bottom chord. All I found was “2400F 2.0E.” What am I looking for? The other chords only have material stamps. Can you tell me what kind of information I should be looking for to find out who the manufacturer was?

Question: 

What is the recommended way to frame gable end overhangs?

Question: 

Do you have information on purlin grades and species to meet 50 psf top chord live load using 2x4s on edge 24 in. O.C. over trusses at 6 ft. O.C.?

Question: 

A condominium project I am involved with is experiencing a sound transfer problem through the floor/ceiling assembly between the first and second floor. You can hear every footstep, from an adult to a child. The floor assembly consists of a carpet and pad, 3/4 in. OSB sub-flooring, 15 in. deep wood trusses at 16 in. on center, 9 in. fiberglass batt insulation and a 5/8 in. gypsum board ceiling. The trusses span 20 ft. with air/heat ducts between the trusses. Will an additional layer of 5/8 in. gypsum board attached to 7/8 in.

Question: 

We have been specifying laminated veneer lumber (LVL) beams for some time now. The plans usually state, “Beam to be engineered and supplied by truss manufacturer.” What kind of liability issues do I need to watch out for?

Question: 

I am a building designer on a salt storage building project. I would like to use metal plate connected wood trusses in the design. What should I specify for the metal connector plates?

Question: 

I am conducting an investigation on the costs associated with building a 15,000 sq. ft. addition to an existing school building. I need to determine if wood trusses, steel bar joists or light gauge steel trusses would be the most economical material for the building system. The truss spans range from 42 ft. to 56 ft.

Question: 

We are building a garage with a bedroom and bathroom and trying to find out what type of floor joists and roof trusses to use. The garage will be a 26 ft. by 32 ft. with a 26 ft. by 32 ft. room upstairs. But we don't want to have posts in the middle of the garage to help support the weight of the second floor.

Question: 

We would like to know if there is a problem with using wood floor trusses with masonry bearing walls without a ledger. Our local supplier has told me that encasing the wood truss in the masonry wall could be detrimental to the truss due to moisture. What, if any, suggestions do you have for this condition? If a bottom chord bearing is used, do the trusses need fire cuts? The two-story building contains masonry bearing walls with wood trusses on the second floor and wood trusses at the roof.